Testing Parameters:
|
Testing and Evaluating Methods
- Leakage:
- differential pressure method related by absolut pressure
- testing media air
- testing pressure 1 bar
- resolution 5 mbar
- Silhouette:
- image processing and evaluation of the silhouette for outstanding rubber film regarding the metal part, respectively the square dimensions
- evaluation and output as:
good / reject / repair part
Technical Data of the fully automatical handling and testing station
- bulk ware processing
- automatical insertion, separation, direction check (upside down),
leak and silhouette test- cycle time 2 sec.